This site is part of the Global Exhibitions Division of Informa PLC

This site is operated by a business or businesses owned by Informa PLC and all copyright resides with them. Informa PLC's registered office is 5 Howick Place, London SW1P 1WG. Registered in England and Wales. Number 3099067.

Informa

Keeping Afloat in a Rising Tide of Waterborne HAIs: 8 Facts Healthcare Leaders Must Know

Article

Continued from page 2

References

  1. Kievens RM, Edwards JR, Richards CL, et al. Estimating Healthcare-Associated Infections and Deaths in U.S. Hospitals 2002. Public Health Reports.2007; 122:160-166.
2. http://www.yourlawyer.com/articles/read/10870  .
  3. http://www.mysanantonio.com/news/local_news/52_million_settles_suit_over_hospital_outbreak.html .
 4. http://www.redorbit.com/news/health/532374/family_of_legionnaires_victim_files_lawsuit/index.html .
 5. http://www.nypost.com/seven/04092007/news/regionalnews/legionnaire_death_suit_regionalnews_denise_buffa.htm .
 6. http://www.nj.com/news/index.ssf/2008/09/legionnaires_disease_strikes_s.html .
  7. Prince A. Biofilms, antimicrobial resistance, and airway infection. N Engl J Med. 2002;347:1110-1111.
8. Federal Register. “Part II: Department of Health and Human Services Centers for Medicare & Medicaid Services 42 CFR Parts 411, 412, 413, 422, and 489 Medicare Program; Changes to the Hospital Inpatient Prospective Payment Systems and Fiscal Year 2009 Rates…” Tuesday, August 19, 2008. 73(161):48471-48487.
9. Anaissie EJ, Penzak SR, Digani MC. The hospital water supply as a source of nosocomial infections: a plea for action. Arch Intern Med. 2002;162:1483-1492.
10. Trautmann M, Lepper P, Haller M. Ecology of Pseudomonas aeruginosa in the intensive care unit and the evolving role of water outlets as a reservoir of the organism. Am J Infect Control. 2005;33(5)(suppl 1):S41-S49.
11. http://www.textbookofbacteriology.net/pseudomonas.html .
12. Reuter S, Sigge A,  Heidemarie W, Trautmann M. Analysis of transmission pathways of Pseudomonas aeruginosa between patients and tap water outlets. Crit Care Med. 2002;30(10):2222-2228.
13. Blanc DS. et al., “Faucets as a reservoir of endemic Pseudomonas aeruginosa colonization/infections in intensive care units” Intensive Care Med. 2004;30:1964-1968.
14. Cervia JS, Ortolano GA, Canonica FP. “Hospital Tap Water: A Reservoir of Risk for Health Care-Associated Infection.” Infect Dis in Clin Practice. 2008;16(6):349-353.
15. http://www.lapublichealth.org/ACD/docs/Legionnaires/Legionella_Guidelines_Final.pdf
16. http://www.osha.gov/dts/osta/otm/legionnaires/sampling.html
17. http://www.who.int/water_sanitation_health/emerging/Legionella.pdf 
 18. http://www1.va.gov/vhapublications/ViewPublication.asp?pub_ID=1654
19.  http://www.cdc.gov/ncidod/dbmd/diseaseinfo/legionellosis_g.htm
20. http://www.Legionella.org.
21. http://www.osha.gov/dts/osta/otm/legionnaires/conf_outbreaks.html#Control
 22. Guidelines for Environmental Infection Control in Health-Care Facilities: Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). MMWR. June 6, 2003;52(RR10);1-42.
23. Squier CL, Stout JE, Krsytofiak S, et al. A proactive approach to prevention of health care-acquired Legionnaires' disease: the Allegheny County (Pittsburgh) experience. Am J Infect Control. 2005; Aug;33(6):360-7.
24. Reasoner, D.J., Geldreich, E.E., A new medium for the enumeration and subculture of bacteria from                potable water. Appl and Environ Microbiol. 1985; 49(1):1-7.
25. Donlan RM, Costerton JW. Biofilms: survival mechanisms of clinically relevant microorganisms. Clin Microbiol Rev. 2002;15(2):167-193.
26. Lindsay D, von Holy A. Bacterial biofilms within the clinical setting: what healthcare professionals should know. J Hosp Infect. 2006;64:313-325.
27.  Costerton JW, Lewandowski Z, Caldwell DE, et al. Microbial biofilms. Annu Rev Microbiol. 1995;49:711-745.
28. Donlan RM. Biofilms: microbial life on surfaces. Emerg Infect Dis. 2002;8:881-890.
29. Lindsay D, von Holy A. Different responses of planktonic and attached Bacillus subtilis and Pseudomonas fluorescens to sanitizer treatment. J Food Prot.1999;62:368-379.
30. Dodds MG, Grobe J, Stewart PS. Modeling biofilm antimicrobial resistance. Biotechnol Bioeng. 2000;68:456-465.
31.  Meyer B. Approaches to prevention, removal and killing of biofilms. Int Biodeterior Biodegradation. 2003;51:249-253.
32. Hall-Stoodley L, Costerton JW, Stoodley P. Bacterial biofilms: from the natural environment to infectious diseases. Nat Rev Microbiol. 2004;2:95-108.
33. Hall-Stoodley L, Stoodley P. Biofilm formation and dispersal and the transmission of human pathogens. Trends Microbiol. 2005;13:7-10.
34. Jefferson KK. What drives bacteria to produce a biofilm? FEMS Microbiol Lett. 2004;236:163-173.
35. Drenkard E, Ausubel FM. Pseudomonas biofilm formation and antimicrobial resistance are linked to phenotypic variation. Nature. 2002;416:740-743.
36. Mouchtouri V, Velonakis E, Hadjichristodoulou C.  Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species. Am J Infect Control. 2007 Nov;35(9):623-7.
  37. Lasheras A, Boulestreau H, Rogues AM, Ohayon-Courtes C, Labadie JC, Gachie JP.  Influence of amoebae and physical and chemical characteristics of water on presence and proliferation of Legionella species in hospital water systems. Am J Infect Control. 2006 Oct;34(8):520-5.
  38. Saby S, Vidal A, Suty H.  Resistance of Legionella to disinfection in hot water distribution systems. Water Sci Technol. 2005;52(8):15-28.
  39. Perola O, Kauppinen J, Kusnetsov J, Kärkkäinen UM, Lück PC, Katila ML Persistent Legionella pneumophila colonization of a hospital water supply: efficacy of control methods and a molecular epidemiological analysis. APMIS. 2005 Jan;113(1):45-53.
  40. Scaturro M, Dell'eva I, Helfer F, Ricci ML.  Persistence of the same strain of Legionella pneumophila in the water system of an Italian hospital for 15 years. Infect Control Hosp Epidemiol. 2007 Sep;28(9):1089-92. Epub 2007 Jul 3.
  41. Clevenger T, Wu Y, Degruson E, Brazos B, Banerji S.  Comparison of the inactivation of Bacillus subtilis spores and MS2 bacteriophage by MIOX, ClorTec and hypochlorite.  J Appl Microbiol. 2007 Dec;103(6):2285-90.
  42. Richardson SD, Plewa MJ, Wagner ED, Schoeny R, Demarini DM.  Occurrence, genotoxicity, and carcinogenicity of regulated and emerging disinfection by-products in drinking water: A review and roadmap for research.  Mutat Res. 2007 Nov-Dec;636(1-3):178-242
  43. Blatchley ER 3rd, Gong WL, Alleman JE, Rose JB, Huffman DE, Otaki M, Lisle JT.  Effects of wastewater disinfection on waterborne bacteria and viruses.  Water Environ Res. 2007 Jan;79(1):81-92
  44. Berry D, Xi C, Raskin L.  Microbial ecology of drinking water distribution systems.  Curr Opin Biotechnol. 2006 Jun;17(3):297-302. Epub 2006 May 15.
  45. Loret JF, Robert S, Thomas V, Cooper AJ, McCoy WF, Lévi Y.  Comparison of disinfectants for biofilm, protozoa and Legionella control.  J Water Health. 2005 Dec;3(4):423-33.
  46. Zhang Z, McCann C, Stout JE, Piesczynski S, Hawks R, Vidic R, Yu VL.  Safety and efficacy of chlorine dioxide for Legionella control in a hospital water system.  Infect Control Hosp Epidemiol. 2007 Aug;28(8):1009-12.
 47.  Rand JL, Hofmann R, Alam MZ, Chauret C, Cantwell R, Andrews RC, Gagnon GA.  A field study evaluation for mitigating biofouling with chlorine dioxide or chlorine integrated with UV disinfection.  Water Res. 2007 May;41(9):1939-48
  48. Chen C, Zhang XJ, He WJ, Han HD.  Simultaneous control of microorganisms and disinfection by-products by sequential chlorination. Biomed Environ Sci. 2007 Apr;20(2):119-25.
 49.  Hua G, Reckhow DA.  Characterization of disinfection byproduct precursors based on hydrophobicity and molecular size. Environ Sci Technol. 2007 May 1;41(9):3309-15.
  50. Goel S, Bouwer EJ.  Factors influencing inactivation of Klebsiella pneumoniae by chlorine and chloramine.  Water Res. 2004 Jan;38(2):301-8. 
  51. Cachafeiro SP, Naveira IM, García IG.  Is copper-silver ionisation safe and effective in controlling Legionella?  J Hosp Infect. 2007 Nov;67(3):209-16.
  52. Huang HI, Shih HY, Lee CM, Yang TC, Lay JJ, Lin YE.  In vitro efficacy of copper and silver ions in eradicating Pseudomonas aeruginosa, Stenotrophomonas maltophilia and Acinetobacter baumannii: Implications for on-site disinfection for hospital infection control. Water Res. 2007 Jul 12.
  53. Mòdol J, Sabrià M, Reynaga E, Pedro-Botet ML, Sopena N, Tudela P, Casas I, Rey-Joly C. Hospital-acquired legionnaires disease in a university hospital: impact of the copper-silver ionization system.  Clin Infect Dis. 2007 Jan 15;44(2):263-5.
  54. Nessim Y, Gehr R. Fouling mechanisms in a laboratory-scale UV disinfection system. Water Environ Res. 2006 Nov;78(12):2311-23.
 55.  Mori M, Hamamoto A, Takahashi A, Nakano M, Wakikawa N, Tachibana S, Ikehara T, Nakaya Y, Akutagawa M, Kinouchi Y.  Development of a new water sterilization device with a 365 nm UV-LED. Med Biol Eng Comput. 2007 Dec;45(12):1237-41.
  56. Oh BS, Park SJ, Jung YJ, Park SY, Kang JW.  Disinfection and oxidation of sewage effluent water using ozone and UV technologies. Water Sci Technol. 2007;55(1-2):299-306.
 57.  Lin, Y.E., Shih, H.Y., Stout, J.E. Efficacy of Point-of-Use Water Filter in Removing Nosocomial Infection-Associated Waterborne Pathogens in a Laboratory Model Plumbing System.  Society of Healthcare Epidemiology of America Annual Meeting 2009; Poster 101.
 58. Sheffer, P., J. Stout, M. Wagener, and R. Muder. Efficacy of new point-of-use water filter for preventing exposure to Legionella and waterborne bacteria.  Amer. J. Infect. Cont. 2005;33(5) Supplement 1:S20-S25.
59. Vonberg, R.P., T. Eckmanns, J. Bruderek, H. Ruden, and P. Gastmeier. Use of terminal tap water filter systems for prevention of nosocomial legionellosis. J. Hosp. Infect. 2005;60:159-162.
60. Vianelli, N. et al Resolution of a Pseudomonas aeruginosa outbreak in a hematology unit with the use of disposable sterile water filters. Haematologica.2006;91(7):983-985.
61. Trautmann, M., H. Royer, E. Helm, W. May, and M. Haller. Pseudomonas aeruginosa: new insights into transmission pathways between hospital water and patients. Filtration. 2004;1(Supplement 1): 63-70.
62. Van der Mee-Marquet, N et al. Water microfiltration: a procedure to prevent Pseudomonas aeruginosa infection.  XVI Congres Nat. Soc. Franc. D’Hyg. Hospitaliere, Water and Hospital Symposium.2005;Reims, France. Abstract S.137.
 63. LaFerriere, C. Infection control measures vs. waterborne microbes in the NICU. SHEA Annual Meeting Poster Session. 2006;Chicago.
64. Cervia J.S., Farber B., Armellino D., Klocke J., Bayer R.L., McAlister M., Stanchfield I., Canonica F.P.,  Ortolano G.A.  Point-of-use water filtration reduces healthcare-associated infections in bone marrow transplant recipients. Transpl Infect Dis. 2010 Jun;12(3):238-41. Epub 2009 Sep 25.
65. Holmes C., Cervia J.S., Ortolano G.A., Canonica F.P. Preventive efficacy and cost-effectiveness of point-of-use water filtration in a subacute care unit. Am J Infect Control. 2010 Feb;38(1):69-71. Epub 2009 Aug 25.
 66. Rogues, A-M,  H. Boulestreau,, A. Lashe´ras, A. Boyer, D. Gruson , C. Merle, Y. Castaing, C.M. Be´bear, J.-P. Gachie. Contribution of tap water to patient colonization with Pseudomonas aeruginosa in a medical intensive care unit. J Hosp Infect. 2007; 67:72-78.
67. Roberts, R.R., R.D. Scott II, R. Cordell et al. The use of economic modeling to determine the hospital costs associated with nosocomial infections.  Clin. Infect. Dis. 2003;36(11):1424-1432.
68. Zahn, C. and M.R. Miller. Excess length of stay, charges, and mortality attributable to medical injuries during hospitalization. JAMA. 2003;290(14):1868-1874.
 69. Lucado, J., Paez, K., Andrews, R., Steiner, C. Adult Hospital Stays with Infections Due to Medical Care, 2007. Agency for Healthcare Research and Quality, Healthcare Cost and Utilization Project. Statistical Brief #94. August 2010.
70. Hall, J., G. Hodgson, and K.G. Kerr. Provision of safe potable water for immunocompromised patients in hospital. J. Hosp. Infect. 2004;58:155-158.
71. Trautmann, M., T. Michalsky, H. Wiedeck, V. Radosavljevic, and M. Ruhnke. Tap water colonization with Pseudomonas aeruginosa in a surgical intensive care unit (ICU) and relation to Pseudomonas infections of ICU patients. Infect. Control Hosp.Epidemiol. 2001;22(1):49-52.
72. Kozicki, Z. A. A call for a new standard for water quality in health care facilities. 12th World Congress on Public Health. Istanbul, Turkey. April 29, 2009.
73. Halabi, M., M. Weisholzer-Pittl, J. Dchoberj, and H. Mittermeyer. Non-touch fittings in hospitals: a possible source of P. aeruginosa and Legionella spp. J Hosp Infect. 2001;49(2):117-21.
74.  Merrer, J., E. Girou, and D. Ducellier. Should electronic faucets be used in intensive care and hematology units?  Intensive Care Med. 2005;31:1715-1718.
75. Chaberny, I., and P. Gastmeier. Should electronic faucets be recommended in hospitals? Infect. Cont. Hosp. Epidemiol. 2004;25:997-1000.

 

 

« Previous123Next »