Ultraviolet C light disinfection to clean unoccupied patient rooms significantly reduced C. difficile infections (CDI) in high-risk patients who later occupied those rooms, according to a study published today in Infection Control & Hospital Epidemiology. The no-touch device, used after patients with CDI were discharged from the hospital, also resulted in substantial healthcare savings, estimated between $350,000 and $1.5 million annually.
“UV light disinfection is a fast, safe, and effective technology to reduce the risk of C. difficile infection associated with the hospital environment,” said David Pegues, MD, lead author of the study and a professor of medicine in the Perelman School of Medicine at the University of Pennsylvania. “The success of this technology is dependent on Environmental Services employees as a critical partner in our ongoing efforts to eliminate hospital-acquired infections such as C. difficile and to improve patient safety.”
The study was conducted in three hematology-oncology units at the Hospital of the University of Pennsylvania during a one-year period (February 2014-January 2015). Results showed that adding UV disinfection to typical disinfection protocols reduced the incidence of CDI by 25 percent among new patients in these units, compared to the prior year. At the same time, CDI rates increased 16 percent in the non-study units during this period. The team found that using the ultraviolet robot after a room cleaning by members of the Environmental Services team not only reduced the number of infections, but did so without adversely impacting room turnaround time. According to this study, room cleaning took only five minutes longer on average compared to non-study units.
“These findings have real implications for both health systems and patients. The effectiveness and efficiency of UV-C robots make it a practical and cost effective technology that will benefit hospitals around the country and save people’s lives,” said Pegues.
The technique, known as ultraviolet wavelength C germicidal irradiation, uses short-wavelength ultraviolet light to kill microorganisms. CDI is one of the most common healthcare-acquired infections in the United States and is associated with serious complications. It is resistant to many surface disinfectants and can persist on surfaces, making it an ongoing risk for transmission to patients.
While the UV disinfection device proved to be effective at reducing CDI incidence, it showed no effect on other healthcare-associated infections, such as methicillin-resistant Staphylococcus aureus (MRSA).
David Pegues, Jennifer Han, Cheryl Gilmar, Brooke McDonnell, Steven Gaynes. “Impact of Ultraviolet Germicidal Irradiation for Terminal Room Disinfection on C.
difficile Infection Incidence among Hematology Oncology Patients.” Web (Oct. 6, 2016).
Source: Society for Healthcare Epidemiology of America
Streamlined IFU Access Boosts Infection Control and Staff Efficiency
June 17th 2025A hospital-wide quality improvement project has transformed how staff access critical manufacturer instructions for use (IFUs), improving infection prevention compliance and saving time through a standardized, user-friendly digital system supported by unit-based training and interdepartmental collaboration.
Spring Into Safety: How Seasonal Deep Cleaning Strengthens Hospital Infection Control
June 13th 2025Rooted in ancient rituals of renewal, spring-cleaning has evolved from cultural tradition to a vital infection prevention strategy in modern hospitals—one that blends seasonal deep cleaning with advanced disinfection to reduce pathogens, improve air quality, and protect patients.
AHE Exchange Summit 2025 Brings EVS and Infection Prevention Experts Together in Columbus, Ohio
June 9th 2025The Association for the Health Care Environment (AHE) is set to host its largest event of the year—Exchange Summit 2025—from June 8 to 11 in Columbus, Ohio. With over 600 environmental services (EVS) professionals expected to attend, this year’s conference focuses heavily on infection prevention, interdepartmental collaboration, and education that empowers frontline health care support leaders to improve patient safety and operational efficiency.
Far UV-C Light Shows Promise for Decontaminating Medical Equipment in Clinical Settings
June 4th 2025Manual cleaning gaps on shared hospital equipment can undermine infection control efforts. New research shows far UV-C light can serve as a safe, automated backup to reduce contamination in real-world clinical settings.