Hot Tubs, Swimming Pools Not as Clean as You May Think

Hot tubs and swimming pools are not always as clean as you might think, even when disinfected. In a new study in ACS' Environmental Science & Technology, scientists have found that the more these facilities are used, the more potentially harmful compounds they contain.

Disinfectants such as chlorine kill pathogens in hot tubs and swimming pools, whether they are personal or public facilities. But disinfectants also react with sweat, urine and other substances that users add to the water. Studies of swimming pools have identified many of the resulting compounds, called disinfection byproducts. And testing has shown that they can cause genetic damage to cells in lab settings. Other reports have found that some people who swim or work in and around pools have higher rates of certain health problems, including respiratory symptoms and bladder cancer. Susan D. Richardson and colleagues took a closer look at hot tubs, in addition to pools, to help flesh out potential problems with disinfection byproducts.

The researchers sampled water from public and private hot tubs and pools from tap to basin, and after both normal and intense use. They identified more than 100 disinfection byproducts in the water and tested extracts of the samples for their potential to cause genetic damage to cells in the lab. On average, pool and hot tub samples were 2.4 and 4.1 times more mutagenic, respectively, than the original tap water used to fill them.

Heavy use increased mutagenic potencies further. But, the researchers say, pool and hot tub operators could reduce disinfection byproducts by cleaning facilities and changing water more frequently. In addition, they could encourage swimmers to shower before sliding in and to use toilets when needed.

Source: American Chemical Society
 


Related to this article

Water  (Adobe Stock 456102510 by stockphoto-graf)
Understanding current water quality is a starting point for ST108 implementation. John Kimsey, vice president of processing optimization and customer success for STERIS, spoke about his HSPA presentation on assessing readiness, distinguishing system qualification from routine testing, and understanding where water samples should be collected.
AORN26 New Orleans 2026  (Adobe Stock)
Missing instruments and processing delays can strain OR–SPD relationships. At AORN 2026, John Kimsey, vice president of processing optimization and customer success for STERIS, discusses understanding root causes, exploring off-site reprocessing for ambulatory surgical centers, and using hands-on simulation to help surgical teams see sterile processing from a different perspective.