Study Shows CHG/Alcohol Solution Most Effective for Disinfecting Needleless Access Sites

Clinical investigators recently released results from the first and only randomized, cross-over, prospective, comparative effectiveness clinical study evaluating the benefits of a 3.15 percent chlorhexidine gluconate (CHG) and 70 percent isopropyl alcohol over 70 percent isopropyl alcohol alone in disinfecting needleless connectors. The study was funded by the Centers for Disease Control and Prevention (CDC) Epicenters Program and executed by Rush University in Chicago. The results were presented at the 2014 IDWeek meeting in Philadelphia on Oct. 11, 2014.

The findings align with CDC guidelines which state: "Some studies have shown that disinfection of the devices with chlorhexidine/alcohol solutions appears to be most effective in reducing colonization."(1) The investigators determined that the CHG and alcohol scrub resulted in less needleless connector contamination than an alcohol scrub at a five-second scrub time. Prevantics® Device Swab from PDI, leading provider of infection prevention solutions, is the only 3.15 percent chlorhexidine gluconate and 70 percent isopropyl alcohol solution that has received market authorization from the Food and Drug Administration (FDA) for disinfecting needleless access sites prior to use.

"This study answers a previously unknown clinical question about the most efficacious antiseptic for disinfection of needleless access sites and also ideal prep times," says Hudson Garrett, PhD, vice president of clinical affairs for PDI. "This study demonstrates the importance of targeted efforts to reduce contamination on needleless access sites and ensure evidence-based practices for disinfection of needleless access sites."

The PDI Prevantics® Device Swab is fully compliant with the evidence-based guidelines and recommendations from the Centers for Disease Control and Prevention (CDC), the Infusion Nurses Society, the Association for Vascular Access, and the Association for Professionals in Infection Control and Epidemiology (APIC).

Reference: 1. 2011 Guidelines for the Prevention of Intravascular Catheter-Related Infections, Healthcare Infection Control Practices Advisory Committee, US Centers for Disease Control and Prevention, 2011

Source: PDI




Related to this article

Water  (Adobe Stock 456102510 by stockphoto-graf)
Understanding current water quality is a starting point for ST108 implementation. John Kimsey, vice president of processing optimization and customer success for STERISS, spoke about his HSPA presentation on assessing readiness, distinguishing system qualification from routine testing, and understanding where water samples should be collected.
Image of Pathogens flying   (Adobe Stock weerasak)
Behind every landmark in infection prevention, from antimicrobial stewardship guidelines to the COVID-19 town halls that reached flight attendants and teachers, is a generation of physician-scientists who led SHEA through crises, organizational change, and scientific breakthroughs. Infection Control Today traces 30 years of SHEA presidents and the lasting mark they left on the field.
AORN26 New Orleans 2026  (Adobe Stock)
Missing instruments and processing delays can strain OR–SPD relationships. At AORN 2026, John Kimsey, vice president of processing optimization and customer success for STERIS, discusses understanding root causes, exploring off-site reprocessing for ambulatory surgical centers, and using hands-on simulation to help surgical teams see sterile processing from a different perspective.