Superbugs Ride Air Currents Around Hospital Units

Article

Hospital superbugs can float on air currents and contaminate surfaces far from infected patients beds, according to University of Leeds researchers. The results of the study, which was funded by the Engineering and Physical Sciences Research Council (EPSRC), may explain why, despite strict cleaning regimes and hygiene controls, some hospitals still struggle to prevent bacteria moving from patient to patient.

It is already recognized that hospital superbugs, such as MRSA and C. difficile, can be spread through contact. Patients, visitors or even hospital staff can inadvertently touch surfaces contaminated with bacteria and then pass the infection on to others, resulting in a great stress in hospitals on keeping hands and surfaces clean.

But the University of Leeds research showed that coughing, sneezing or simply shaking the bed linens can send superbugs into flight, allowing them to contaminate recently cleaned surfaces.

PhD student Marco-Felipe King used a biological aerosol chamber, one of a handful in the world, to replicate conditions in one- and two-bedded hospital rooms. He released tiny aerosol droplets containing Staphyloccus aureus from a heated mannequin simulating the heat emitted by a human body. He placed open petri dishes where other patients beds, bedside tables, chairs and washbasins might be and then checked where the bacteria landed and grew.

The results confirmed that contamination can spread to surfaces across a ward. The level of contamination immediately around the patients bed was high but you would expect that. Hospitals keep beds clean and disinfect the tables and surfaces next to beds, says Dr. Cath Noakes, from the Universitys School of Civil Engineering, who supervised the work. However, we also captured significant quantities of bacteria right across the room, up to 3.5 meters away and especially along the route of the airflows in the room.

We now need to find out whether this airborne dispersion is an important route of spreading infection, adds co-supervisor Dr. Andy Sleigh.

The researchers are hoping that computer modeling will help them determine the risk. The findings have been compared to airflow simulations of the mock hospital rooms and the research team have shown that they are able to accurately predict how airborne particles can be deposited on surfaces.

Using our understanding of airflow dynamics, we can now use these models to investigate how different ward layouts and different positions of windows, doors and air vents could help prevent microorganisms being deposited on accessible surfaces, says King.

The international design and engineering firm Arup, which designs hospitals, part sponsored the study. Phil Nedin, director and global healthcare business leader at Arup, says: We are looking at healthcare facilities of the future and it is important that we look at key issues such as infection control. Being involved in microbiological studies that inform airflow modeling in potentially infectious environments allows us to get a clear understanding of the risks in these particular environments.

The paper, Bioaerosol Deposition in Single and Two-Bed Hospital Rooms: A Numerical and Experimental Study, was published in the journal Building and Environment.

This research is funded by an EPSRC Challenging Engineering grant held by Dr. Cath Noakes. Marco-Felipe Kings PhD was also partially sponsored by Arup.

Reference: M.F. King, C.J. Noakes, P.A. Sleigh, M.A. Camargo-Valero. Bioaerosol Deposition in Single and Two-Bed Hospital Rooms: A Numerical and Experimental Study. Building and Environment. 2012.

Source: University of Leeds

Related Videos
Infection Control Today Topic of the Month: Mental Health
Infection Control Today Topic of the Month: Mental Health
Cleaning and sanitizing surfaces in hospitals  (Adobe Stock 339297096 by Melinda Nagy)
Set of white bottles with cleaning liquids on the white background. (Adobe Stock 6338071172112 by zolnierek)
Association for the Health Care Environment (Logo used with permission)
Woman lying in hospital bed (Adobe Stock, unknown)
Photo of a model operating room. (Photo courtesy of Indigo-Clean and Kenall Manufacturing)
Mona Shah, MPH, CIC, FAPIC, Construction infection preventionist  (Photo courtesy of Mona Shah)
UV-C Robots by OhmniLabs.  (Photo from OhmniLabs website.)
CDC  (Adobe Stock, unknown)
Related Content