In the December issue of Infection Control and Hospital Epidemiology, guidelines have been proposed by epidemiologists from Beaumont Health System to reduce the risk of infection from contaminated gels. The recommendations are based on the authors own experiences with an outbreak traced to contaminated ultrasound transmission gel.
In December 2011, researchers uncovered an unusual cluster of Pseudomonas aeruginosa in a cardiovascular surgery intensive care unit during routine infection control surveillance. The outbreak was found to have stemmed from bottles of ultrasound transmission gel that were contaminated during the manufacturing process and that were being used for intraoperative transesophageal echocardiography. This information ultimately led to a national recall of the product.
These gels contain parabens or methyl benzoate that inhibit, but not kill, the growth of bacteria. However, past studies have demonstrated that ultrasound gels do not have antimicrobial properties and could serve as a medium for bacterial growth. Contaminated gels have been found to be the source of other outbreaks of infection in the last two decades.
After our investigation of the Pseudomonas outbreak last year linked the source of the outbreak to contaminated ultrasound gel, we were surprised to find that very little guidance is available on appropriate uses for different ultrasound gel products, says Susan Oleszkowicz, MPH, lead author of the paper.
In their article the authors outline initial guidelines for recommended uses of ultrasound transmission gels, calling on manufacturers of ultrasound gel and professional societies to take an active role in developing recommendations for appropriate and intended use of products.
Suggestions include: 1) the need for sterile, single-dose ultrasound gel in any invasive procedure or procedures involving non-intact skin or fresh surgical wounds; 2) sterile, single-dose ultrasound gel should be used with newborns or critically ill children; 3) multi-dose, non-sterile gel can still be used on intact skin, but containers should be sealed appropriately when not in use, and replaced when empty, rather than refilled.Â
Â
Reference: Oleszkowicz SC, et al. Infections Associated with Use of Ultrasound Transmission Gel: Proposed Guidelines to Minimize Risk. Infection Control and Hospital Epidemiology 33:12 (December 2012).
IP LifeLine: Keeping it Together When Things Fall Apart: Maintaining Balance When Life Gets Messy
July 25th 2024Balancing personal struggles and professional responsibilities during crises requires self-awareness, self-compassion, healthy boundaries, and support networks. Embrace these strategies to navigate and overcome challenges.
Adaptive Clothing Innovations for Medical Treatments: A Journey to Enhance Patient Care
June 18th 2024Chaitenya Razdan, CEO and founder of Care+Wear, discusses the development of adaptive clothing for patients with PICC lines and NICU infants, focusing on comfort, dignity, and infection prevention.