Vanderbilt Performs Implantation of Fully Resorbable Antibacterial Envelope for Cardiac Devices

Article

Vanderbilt Heart and Vascular Institute is the first medical center in the United States to use a new fully resorbable envelope that encloses implantable cardiac devices, such as pacemakers and internal cardioverter defibrillators (ICDs), and helps prevent surgical site infections. The AIGISRx R Antibacterial Envelope from TYRX, Inc. received Food and Drug Administration (FDA) clearance on May 20.

AIGISRx R Antibacterial Envelope is a fully bioresorbable, antibacterial pouch-like mesh envelope that holds cardiac rhythm devices securely in place when implanted in the body. The envelope contains the antimicrobial agents rifampin and minocycline, which are released locally into the tissue, to help reduce infections associated with cardiac implantable electronic devices (CIEDs).

Over the last several decades, the number of cardiac device infections has risen significantly and out of proportion to the number of cardiac device implantations. With more than 500,000 CIED implantations annually in the U.S., it is critical that the infections associated with these types of procedures are avoided to help save lives and money, according to cardiologist Christopher Ellis, MD, assistant professor of medicine, who used the resorbable envelope for the first time on Aug. 7.

The CIED is placed below the collarbone in a pocket the physician creates underneath the skin. Once the device is placed inside the mesh envelope and implanted into the pocket, the antimicrobials are released and the envelope dissolves entirely within about nine weeks.

The infection protection is still there. Its nice to know when I go back into the pocket several years from now, I wont even know it (AIGISRx R) was ever in there, Ellis says.

Research by Ellis and colleagues at Vanderbilt has shown that the AIGISRx Antibacterial Envelope significantly reduced device infections by nearly 90 percent in high-risk patients, compared to patients who did not receive the AIGISRx.

Nationally, patients with surgical site infections following CIED procedures spend additional time in the hospital and undergo repeat surgical procedures to treat the infection. These patients experience significant increases in morbidity and mortality, with one-year mortality rates of greater than 25 percent, and three-year mortality of up to 50 percent, depending on device type.

Cardiac device generators typically need to be replaced every five to eight years due to wear and tear, and each time the procedure is performed, the rate of infection increases exponentially, Ellis says. In addition, there are some patients who are at greater risk of infection due to diabetes, kidney disease and prior device infection.

Newsletter

Stay prepared and protected with Infection Control Today's newsletter, delivering essential updates, best practices, and expert insights for infection preventionists.

Recent Videos
 Brenna Doran PhD, MA, hospital epidemiology and infection prevention for the University of California, San Francisco, and a coach and consultant of infection prevention; Jessica Swain, MBA, MLT, director of infection prevention and control for Dartmouth Health in Lebanon, New Hampshire; and Shanina Knighton, associate professor at Case Western Reserve University School of Nursing and senior nurse scientist at MetroHealth System in Cleveland, Ohio
In a recent discussion with Infection Control Today® (ICT®), study authors Brenna Doran PhD, MA, hospital epidemiology and infection prevention for the University of California, San Francisco, and a coach and consultant of infection prevention; Jessica Swain, MBA, MLT, director of infection prevention and control for Dartmouth Health in Lebanon, New Hampshire; and Shanina Knighton, associate professor at Case Western Reserve University School of Nursing and senior nurse scientist at MetroHealth System in Cleveland, Ohio, shared their insights on how the project evolved and what the findings mean for the future.
 Futuristic UV Sanitizer with Sleek Design on a white background.  (Adobe Stock 1375983522 by Napa)