FDA Permits Marketing of First Test to Identify 11 Causes of Infectious Gastroenteritis

Article

The Food and Drug Administration (FDA) announces that it is allowing marketing for the first test that can simultaneously detect 11 common viral, bacterial, and parasitic causes of infectious gastroenteritis from a single patient sample.
 
Infectious gastroenteritis is an inflammation of the stomach and intestines caused by certain viruses, bacteria, or parasites. Common symptoms include vomiting and diarrhea, which can be more severe in infants, the elderly, and people with suppressed immune systems. Gastroenteritis can be spread easily through person-to-person contact and contaminated food, water, and surfaces.
 
The Centers for Disease Control and Prevention (CDC) reports that between 1999 and 2007 gastroenteritis-associated deaths in the United States increased from nearly 7,000 to more than 17,000 per year. Norovirus and Clostridium difficile accounted for two-thirds of the deaths.
 
The xTAG Gastrointestinal Pathogen Panel (GPP), a multiplexed nucleic acid test, detects the following causes of gastroenteritis:
 
Bacteria
Campylobacter
Clostridium difficile (C. difficile) toxin A/B
Escherichia coli (E. coli) O157
Enterotoxigenic Escherichia coli (ETEC) LT/ST
Salmonella
Shigella
Shigalike Toxin producing E. coli (STEC) stx 1/stx 2
 
Virus
Norovirus
Rotavirus A
 
Parasite
Cryptosporidium
Giardia
 
Tests such as the XTag GPP that can detect viruses, bacteria, and parasites from one sample at the same time can help clinicians more quickly identify and treat whats causing gastroenteritis, says Alberto Gutierrez, PhD, director of the Office of In Vitro Diagnostics and Radiology at the FDAs Center for Devices and Radiological Health. The test could also allow clinicians and public health professionals to more quickly identify and investigate the source of potential gastroenteritis outbreaks.
 
The FDA reviewed data for the xTag GPP through the de novo classification process, a regulatory pathway for medical devices that are generally low- to moderate-risk but are not comparable to an already legally marketed device.
 
The manufacturer demonstrated the performance of the xTAG GPP by collecting samples from 1,407 patients with suspected infectious gastroenteritis and comparing the xTAG GPP results to individual tests that are known to separately and reliably detect the 11 viruses, bacteria, or parasites associated with the xTAG GPP. The manufacturer also ran the test on 203 samples from patients with previously confirmed infectious gastroenteritis, and 313 additional specimens from pediatric patients with suspected infectious gastroenteritis. Results were comparable to the individual tests. Due to the risk of false positives, all positive results from the xTAG GPP need to be confirmed by additional testing.
 
Luminex, Inc., of Austin, Texas, manufactures the xTAG. 
 
Source: FDA 

 

Recent Videos
Mark Wiencek, PhD
Rebecca Crapanzano-Sigafoos, DrPH, CIC, AL-CIP, FAPIC
The CDC’s updated hospital respiratory reporting requirement has added new layers of responsibility for infection preventionists. Karen Jones, MPH, RN, CIC, FAPIC, clinical program manager at Wolters Kluwer, breaks down what it means and how IPs can adapt.
Studying for the CIC using a digital tablet and computer (Adobe Stock 335828989 by NIKCOA)
Infection Control Today's Conversations with the HSPA President, Arlene Bush, CRCST, CER, CIS, SME, DSMD, CRMST
Infection Control Today's Conversations with the HSPA President, Arlene Bush, CRCST, CER, CIS, SME, DSMD, CRMST
Cheron Rojo, BS, FCS, CHL,  CER, CFER, CRCST
Matthias Tschoerner, Dr Sc
Standardizing Cleaning and Disinfection
Concept images of Far-UVC  (Adobe Stock 316993517 by hopenv)
Related Content